| Наименование | Производитель | Корпус | Норма упаковки | Max data rate(Mbps) | Functionality | Max data rate (Mbps) | BUS common voltage(V) | Bus common voltage (V) | Power supply voltage VDD1 (V) | Side1 supply voltage(V) | Side2 supply voltage(V) | Power supply voltage VDD2 (V) | CMTI(kV/us) | CMTI (kV/μs) | Isolation Rating(kV) | Isolation Rating (kV) | Surge test voltage (kV) | Surge test voltage(kV) | Сравнить | Запрос, шт |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| NCA1021S-Q1DNR | Novosense | DFN-8 | T&R 5000 | LIN transceiver | 20kbps | |||||||||||||||
|
Automotive LIN Bus Transceiver
Operating Temperature Range (℃): -40~150
Functionality: LIN transceiver
Qualification: Automotive
Max data rate (Mbps): 20kbps
Supply Voltage VCC (V): 5,5~27
Bus Fault Protection (V): -40~40
|
||||||||||||||||||||
| NCA1021S-Q1SPR | Novosense | SOP-8 | T&R 2500 | LIN transceiver | 20kbps | |||||||||||||||
|
Automotive LIN Bus Transceiver
Operating Temperature Range (℃): -40~150
Functionality: LIN transceiver
Qualification: Automotive
Max data rate (Mbps): 20kbps
Supply Voltage VCC (V): 5,5~27
Bus Fault Protection (V): -40~40
|
||||||||||||||||||||
| NCA1042-DSPR | Novosense | SOP-8 | T&R 2500 | CAN transceiver | 5Mbps | -30~30 | ||||||||||||||
|
Fault Protected High-Speed CAN FD Transceiver with Standby Mode
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Qualification: Industrial
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
Supply Voltage VIO (V): 3~5,5
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -70~70
|
||||||||||||||||||||
| NCA1042B-DSPR | Novosense | SOP-8 | T&R 2500 | CAN transceiver | 5Mbps | -30~30 | ||||||||||||||
|
Fault Protected High-Speed CAN FD Transceiver with Standby Mode
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Qualification: Industrial
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
Supply Voltage VIO (V): 2,8~5,5
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -70~70
|
||||||||||||||||||||
| NCA1042B-Q1DNR | Novosense | DFN-8 | T&R 3000 | CAN transceiver | 5Mbps | -30~30 | ||||||||||||||
|
Automotive Fault Protected High-Speed CAN FD Transceiver with Standby Mode
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Qualification: Automotive
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
Supply Voltage VIO (V): 2,8~5,5
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -58~58
|
||||||||||||||||||||
| NCA1042B-Q1SPR | Novosense | SOP-8 | T&R 2500 | CAN transceiver | 5Mbps | -30~30 | ||||||||||||||
|
Automotive Fault Protected High-Speed CAN FD Transceiver with Standby Mode
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Qualification: Automotive
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
Supply Voltage VIO (V): 2,8~5,5
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -58~58
|
||||||||||||||||||||
| NCA1042BN-Q1DNR | Novosense | DFN-8 | T&R 3000 | CAN transceiver | 5Mbps | -30~30 | ||||||||||||||
|
Automotive Fault Protected High-Speed CAN FD Transceiver with Standby Mode
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Qualification: Automotive
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
Supply Voltage VIO (V): 2,8~5,5
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -58~58
|
||||||||||||||||||||
| NCA1042BN-Q1SPR | Novosense | SOP-8 | T&R 2500 | CAN transceiver | 5Mbps | -30~30 | ||||||||||||||
|
Automotive Fault Protected High-Speed CAN FD Transceiver with Standby Mode
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Qualification: Automotive
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
Supply Voltage VIO (V): 2,8~5,5
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -58~58
|
||||||||||||||||||||
| NCA1051-DSPR | Novosense | SOP-8 | T&R 2500 | CAN transceiver | 5Mbps | -30~30 | ||||||||||||||
|
Fault Protected High-Speed CAN FD Transceiver
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Qualification: Industrial
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
Supply Voltage VIO (V): 3~5,5
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -70~70
|
||||||||||||||||||||
| NCA1051A-DSPR | Novosense | SOP-8 | T&R 2500 | CAN transceiver | 5Mbps | -30~30 | ||||||||||||||
|
Fault Protected High-Speed CAN FD Transceiver
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Qualification: Industrial
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
Supply Voltage VIO (V): 2,8~5,5
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -70~70
|
||||||||||||||||||||
| NCA1051A-Q1SPR | Novosense | SOP-8 | T&R 2500 | CAN transceiver | 5Mbps | -30~30 | ||||||||||||||
|
Automotive Fault Protected High-Speed CAN FD Transceiver
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Qualification: Industrial
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
Supply Voltage VIO (V): 3~5,5
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -70~70
|
||||||||||||||||||||
| NCA1051AN-DSPR | Novosense | SOP-8 | T&R 2500 | CAN transceiver | 5Mbps | -30~30 | ||||||||||||||
|
Fault Protected High-Speed CAN FD Transceiver
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
Supply Voltage VIO (V): 2,8~5,5
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -70~70
|
||||||||||||||||||||
| NCA1145-Q1DNKR | Novosense | DFN-14 | T&R 2500 | CAN transceiver | 5Mbps | -12~12 | ||||||||||||||
|
Automotive-grade high-speed CAN FD transceiver with remote wake up and fault protection
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Qualification: Automotive
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -12~12
Supply Voltage VIO (V): 2,85~5,5
Supply Voltage VCC (V): 4,75~5,5
Bus Fault Protection (V): -70~70
|
||||||||||||||||||||
| NCA1145-Q1SPKR | Novosense | SOP-14 | T&R 2500 | CAN transceiver | 5Mbps | -12~12 | ||||||||||||||
|
Automotive-grade high-speed CAN FD transceiver with remote wake up and fault protection
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Qualification: Automotive
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -12~12
Supply Voltage VIO (V): 2,85~5,5
Supply Voltage VCC (V): 4,75~5,5
Bus Fault Protection (V): -70~70
|
||||||||||||||||||||
| NSI1042-DSWR | Novosense | SOP-16 | T&R 1000 | CAN transceiver | 5Mbps | -30~30 | 2.5~5.5 | 4.5~5.5 | 150 | 5 | 10 | |||||||||
|
High-Performance Isolated CAN Transceiver
Surge test voltage (kV): 10
Operating Temperature Range (℃): -40~125
Power supply voltage VDD1 (V): 2.5~5.5
Functionality: CAN transceiver
Power supply voltage VDD2 (V): 4.5~5.5
Qualification: Industrial
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
CMTI (kV/μs): 150
Isolation Rating (kV): 5
Bus Fault Protection (V): -70~70
|
||||||||||||||||||||
| NSI1042-DSWVR | Novosense | SOP-8 | T&R 1000 | CAN transceiver | 5Mbps | -30~30 | 2.5~5.5 | 4.5~5.5 | 150 | 5 | 10 | |||||||||
|
High-Performance Isolated CAN Transceiver
Surge test voltage (kV): 10
Operating Temperature Range (℃): -40~125
Power supply voltage VDD1 (V): 2.5~5.5
Functionality: CAN transceiver
Power supply voltage VDD2 (V): 4.5~5.5
Qualification: Industrial
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
CMTI (kV/μs): 150
Isolation Rating (kV): 5
Bus Fault Protection (V): -70~70
|
||||||||||||||||||||
| NSI1042-Q1SWR | Novosense | SOP-16 | T&R 2500 | CAN transceiver | 5Mbps | -30~30 | 2.5~5.5 | 4.5~5.5 | 150 | 5 | 10 | |||||||||
|
Isolated CAN Transceiver
Surge test voltage (kV): 10
Operating Temperature Range (℃): -40~125
Power supply voltage VDD1 (V): 2.5~5.5
Functionality: CAN transceiver
Power supply voltage VDD2 (V): 4.5~5.5
Qualification: Automotive
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
CMTI (kV/μs): 150
Isolation Rating (kV): 5
|
||||||||||||||||||||
| NSI1042-Q1SWVR | Novosense | SOP-8 | T&R 2500 | CAN transceiver | 5Mbps | -30~30 | 2.5~5.5 | 4.5~5.5 | 150 | 5 | 10 | |||||||||
|
Isolated CAN Transceiver
Surge test voltage (kV): 10
Operating Temperature Range (℃): -40~125
Power supply voltage VDD1 (V): 2.5~5.5
Functionality: CAN transceiver
Power supply voltage VDD2 (V): 4.5~5.5
Qualification: Automotive
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
CMTI (kV/μs): 150
Isolation Rating (kV): 5
|
||||||||||||||||||||
| NSI1042C-DSWR | Novosense | SOP-16 | T&R 2500 | CAN transceiver | 5Mbps | -30~30 | 2.5~5.5 | 4.5~5.5 | 150 | 5 | 10 | |||||||||
|
Cost-effective Isolated CAN Transceivers
Surge test voltage (kV): 10
Operating Temperature Range (℃): -40~125
Power supply voltage VDD1 (V): 2.5~5.5
Functionality: CAN transceiver
Power supply voltage VDD2 (V): 4.5~5.5
Qualification: Industrial
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
CMTI (kV/μs): 150
Isolation Rating (kV): 5
|
||||||||||||||||||||
| NSI1042C-DSWVR | Novosense | SOP-8 | T&R 2500 | CAN transceiver | 5Mbps | -30~30 | 2.5~5.5 | 4.5~5.5 | 150 | 5 | 10 | |||||||||
|
Cost-effective Isolated CAN Transceivers
Surge test voltage (kV): 10
Operating Temperature Range (℃): -40~125
Power supply voltage VDD1 (V): 2.5~5.5
Functionality: CAN transceiver
Power supply voltage VDD2 (V): 4.5~5.5
Qualification: Industrial
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
CMTI (kV/μs): 150
Isolation Rating (kV): 5
|
||||||||||||||||||||
| NSI1050-DDBR | Novosense | DUB-8 | T&R 800 | CAN transceiver | 1Mbps | -12~12 | 2.5~5.5 | 4.5~5.5 | 100 | 3 | 10 | |||||||||
|
High-Performance Isolated CAN Transceiver
Surge test voltage (kV): 10
Operating Temperature Range (℃): -40~125
Power supply voltage VDD1 (V): 2.5~5.5
Functionality: CAN transceiver
Power supply voltage VDD2 (V): 4.5~5.5
Qualification: Industrial
Max data rate (Mbps): 1Mbps
Bus common voltage (V): -12~12
CMTI (kV/μs): 100
Isolation Rating (kV): 3
Bus Fault Protection (V): -40~40
|
||||||||||||||||||||
| NSI1050-DSWR | Novosense | SOP-16 | T&R 1000 | CAN transceiver | 1Mbps | -12~12 | 2.5~5.5 | 4.5~5.5 | 100 | 5 | 10 | |||||||||
|
High-Performance Isolated CAN Transceiver
Surge test voltage (kV): 10
Operating Temperature Range (℃): -40~125
Power supply voltage VDD1 (V): 2.5~5.5
Functionality: CAN transceiver
Power supply voltage VDD2 (V): 4.5~5.5
Qualification: Industrial
Max data rate (Mbps): 1Mbps
Bus common voltage (V): -12~12
CMTI (kV/μs): 100
Isolation Rating (kV): 5
Bus Fault Protection (V): -40~40
|
||||||||||||||||||||
| NSI1052-DSWR | Novosense | SOP-16 | T&R 1000 | CAN transceiver | 5Mbps | -30~30 | 2.5~5.5 | 4.5~5.5 | 150 | 5 | 10 | |||||||||
|
High-Performance Isolated CAN Transceiver
Surge test voltage (kV): 10
Operating Temperature Range (℃): -40~125
Power supply voltage VDD1 (V): 2.5~5.5
Functionality: CAN transceiver
Power supply voltage VDD2 (V): 4.5~5.5
Qualification: Industrial
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
CMTI (kV/μs): 150
Isolation Rating (kV): 5
Bus Fault Protection (V): -70~70
|
||||||||||||||||||||
| NSI1052-Q1SWR | Novosense | SOP-16 | T&R 1000 | CAN transceiver | 5Mbps | -30~30 | 2.5~5.5 | 4.5~5.5 | 150 | 5.7 | 10 | |||||||||
|
Isolated CAN Transceiver
Surge test voltage (kV): 10
Operating Temperature Range (℃): -40~125
Power supply voltage VDD1 (V): 2.5~5.5
Functionality: CAN transceiver
Power supply voltage VDD2 (V): 4.5~5.5
Qualification: Industrial
Max data rate (Mbps): 5Mbps
Bus common voltage (V): -30~30
CMTI (kV/μs): 150
Isolation Rating (kV): 5.7
Bus Fault Protection (V): -58~58
|
||||||||||||||||||||
| XD2551 | XINLUDA | DIP-8 | Tube 50 | CAN transceiver | 1M | |||||||||||||||
|
High-speed CAN Transceiver
Operating Temperature Range (℃): -40~85
Functionality: CAN transceiver
Max data rate (Mbps): 1M
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -42-42
|
||||||||||||||||||||
| XD82C251 | XINLUDA | DIP-8 | Tube 50 | CAN transceiver | 1M | |||||||||||||||
|
CAN transceiver for 24 V systems
Operating Temperature Range (℃): -40~85
Functionality: CAN transceiver
Max data rate (Mbps): 1M
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -36-36
|
||||||||||||||||||||
| XL1042T/3 | XINLUDA | SOP-8 | T&R 2500 | CAN transceiver | FD | |||||||||||||||
|
CAN transceiver with CAN FD and fail-safe features
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Max data rate (Mbps): FD
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): ±58
|
||||||||||||||||||||
| XL1044T/3 | XINLUDA | SOP-8 | T&R 2500 | CAN transceiver | FD | |||||||||||||||
|
High-speed CAN transceiver with Standby mode
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Max data rate (Mbps): FD
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): ±40
|
||||||||||||||||||||
| XL1049T/3 | XINLUDA | SOP-8 | T&R 2500 | CAN transceiver | 5Mbps | |||||||||||||||
|
High-speed CAN transceiver with Standby mode
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Max data rate (Mbps): 5Mbps
Supply Voltage VIO (V): 2,9~5,25
Supply Voltage VCC (V): 4,75~5,25
Bus Fault Protection (V): ±58
|
||||||||||||||||||||
| XL1050 | XINLUDA | SOP-8 | T&R 2500 | CAN transceiver | 1M | |||||||||||||||
|
High-speed CAN transceiver
Operating Temperature Range (℃): -40~85
Functionality: CAN transceiver
Max data rate (Mbps): 1M
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -40-40
|
||||||||||||||||||||
| XL1051T/3 | XINLUDA | SOP-8 | T&R 2500 | CAN transceiver | FD | |||||||||||||||
|
High-speed CAN transceiver
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Max data rate (Mbps): FD
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): ±58
|
||||||||||||||||||||
| XL1057GT/3 | XINLUDA | SOP-8 | T&R 2500 | CAN transceiver | FD | |||||||||||||||
|
High-speed CAN transceiver
Operating Temperature Range (℃): -40~125
Functionality: CAN transceiver
Max data rate (Mbps): FD
Supply Voltage VIO (V): 2,9~5,5
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): ±42
|
||||||||||||||||||||
| XL2551 | XINLUDA | SOP-8 | T&R 2500 | CAN transceiver | 1M | |||||||||||||||
|
High-speed CAN Transceiver
Operating Temperature Range (℃): -40~85
Functionality: CAN transceiver
Max data rate (Mbps): 1M
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -42-42
|
||||||||||||||||||||
| XL82C250 | XINLUDA | SOP-8 | T&R 2500 | CAN transceiver | High Speed | |||||||||||||||
|
CAN controller interface chip
Operating Temperature Range (℃): -40~85
Functionality: CAN transceiver
Max data rate (Mbps): High Speed
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -8 +18
|
||||||||||||||||||||
| XL82C251 | XINLUDA | SOP-8 | T&R 2500 | CAN transceiver | 1M | |||||||||||||||
|
CAN transceiver for 24 V systems
Operating Temperature Range (℃): -40~85
Functionality: CAN transceiver
Max data rate (Mbps): 1M
Supply Voltage VCC (V): 4,5~5,5
Bus Fault Protection (V): -36-36
|
||||||||||||||||||||